Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Electric Type |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Rated current of shell frame level (Inm) | 125A | 250A | 400A | 630A | 800A |
Rated current(In) | (0.41)In adjustable | ||||
Rated working voltage(Ue) | AC400V | ||||
Rated insulation voltage(Ui) | AC1000V | ||||
Rated impulse withstand voltage(Uimp) | 800V | ||||
Ultimate short-circuit sectioning capacity (Icu) | M Type:50KA | M Type:65KA | |||
H Type:65KA | H Type:85KA | ||||
Operating short-circuit segmentation capability(Ics) | M Type:35KA | M Type:50KA | |||
H Type:50KA | H Type:65KA | ||||
Rated short time withstand current (Icw) | 5KA/1S | 10KA/1S | |||
Auxiliary power supply voltage Ue | AC400V | ||||
Applicable pole number | 4P/3P+N | ||||
Rated residual operating current I △ N | Customizable 10 sets of parameters with optional values (factory adjustable 50-1000ma, default setting 300ma/500ma) | ||||
Rated residual non-operating current | I △ NO=-50%I △ N | ||||
Rated limit non driving time (S) | Customizable 3 sets of parameter values (default 0.06/0.2/0.3 adjustable, factory default setting of 0.06) | ||||
Delay reclosing time | (20-60)S | ||||
Classification of action characteristics | AC Type | ||||
Product usage category | B Type |
Residual current alarm | Factory default disable,Users can enable | During wheel display or press reset: | |||
Automatic gear setting (residual current tracking) | Factory default disable,Users can enable | 1. Press to enter the function setting interface | |||
Mutation protection (residual current) | Factory default disable,Users can enable | 2 Enable, the number remains on to | |||
Special wave protection | Factory default disable,Users can enable | indicate enabled | |||
Automatic reclosing | Factory default disable,Users can enable | 3 Disabled, flashing numbers indicate disabled | |||
Incoming test closing | Factory default disable,Users can enable | ||||
Overvoltage protection | Factory (275V ± 5%, can be set by oneself) default disabled,Users can enable | ||||
Undervoltage protection | Factory (275V ± 5%, can be set by oneself) default disabled,Users can enable | ||||
Phase loss protection | Factory default disable,Users can enable | ||||
Full voltage loss protection | Factory default disable,Users can enable | ||||
Overload protection | Factory default disable,Users can enable | ||||
Short circuit delay protection | Factory default disable,Users can enable | ||||
Three phase imbalance protection | Factory default disable,Users can enable | ||||
Zero protection | Factory default disable,Users can enable | ||||
Remote segmentation (remote segmentation) | Factory default disable,Users can enable | ||||
Remarks | The activation or prohibition of the above functions shall be based on the product |